A revolving door air curtain is installed above or beside revolving doors to create a high-velocity air barrier. This barrier prevents outside air, debu, and insects from entering while maintaining the indoor climate. By minimizing heat or cold air exchange, the air curtain reduces energy consumption and enhances indoor comfort and cleanliness. It is widely used in commercial buildings, office complexes, rumah sakit, and other places with frequent door usage.
The core component that produces strong and uniform airflow.
Some air curtains include heating elements to provide warm air during winter, increasing comfort when passengers pass by
These clean the air by removing dust and impurities, ensuring the air entering the building is clean.
Includes switches, regulators, and sensors to adjust fan speed, temperature, and operation times, ensuring efficient performance.
Typically made of metal or stainless steel material, it protects internal components and ensures durability.
We can use PTC heater to instead of the heating tube, and axial motor to instead of the centrifugal fan, then it can save much space,and it can install on the front surface of the revolving door.Please check the project photo.
CDAIRTECH provides 7*24h online service and a 2-year warranty. And our quality control department will check each step from production to packaging and delivery.
Air curtain color to match the revolving door color,it can create a cohesive and visually pleasing appearance.
Stainless steel cover to install on the front of the revolving door air curtain.
Easy to install and maintain, it can save time and cost. CDAIRTECH will finish the assemble of air curtain before delivery, when the customer open the package, they only need to install the air curtain on the top of the revolving door and make line connection it ok,
The cover of the air curtain is easy to open, so it will be easy for maintain.No need to remove the air curtain from the revolving door.
Model | CD-100E | CD-150E | CD-200E | CD-250E | CD-300E | |||
Maks. installation height | M | 3.0 | 3.0 | 3.0 | 3.0 | 3.0 | ||
Volume flow rate | Low speed | m³/jam | 2100 | 2800 | 4200 | 4900 | 5600 | |
Medium speed | m³/jam | 2400 | 3200 | 4800 | 5600 | 6400 | ||
High speed | m³/jam | 2700 | 3600 | 5400 | 6300 | 7200 | ||
Maks. sound level | dB(A) | 59 | 60 | 62 | 63 | 64 | ||
Weight of basic unit | kg | 48 | 68 | 88 | 118 | 138 | ||
Electrical heater (three-step. 400 V, 3 Ph, 50 Hz) | ||||||||
Melangkah 1 | kW | 6.0 | 8.0 | 12.0 | 12.0 | 12.0 | ||
Melangkah 2 | kW | 12.0 | 16.0 | 24.0 | 24.0 | 24.0 | ||
Melangkah 3 | kW | 18.0 | 24.0 | 36.0 | 36.0 | 36.0 | ||
△t max. | ℃ | 19.8 | 19.8 | 19.8 | 16.8 | 14.7 |
Model | CD-100W | CD-150W | CD-200W | CD-250W | CD-300W | |||||||
Maks. installation height m | 3.0 | 3.0 | 3.0 | 3.0 | 3.0 | |||||||
Volume flow rate m³/h | Low speed | 2100 | 2800 | 4200 | 4900 | 5600 | ||||||
Medium speed | 2400 | 3200 | 4800 | 5600 | 6400 | |||||||
High speed | 2700 | 3600 | 5400 | 6300 | 7200 | |||||||
Maks. sound level dB | 59 | 60 | 62 | 63 | 64 | |||||||
Weight of basic unit kg | 48 | 68 | 88 | 118 | 138 | |||||||
Electrical connection | Right | Right | Right | Right | Right | |||||||
Technical parameters at high volume flow rate | ||||||||||||
LTHW 90/70 at air intake temperature 15℃ and air discharge temperature 37℃ | ||||||||||||
Heat output kW | 19.9 | 26.6 | 39.9 | 46.6 | 53.3 | |||||||
Flow rate m³/h | 0.82 | 1.34 | 1.85 | 2.36 | 2.88 | |||||||
Water resistance kPa | 0.25 | 1.37 | 2.74 | 6.52 | 10.06 | |||||||
LTHW 80/60 at air intake temperature 15℃ and maximum air discharge temperature | ||||||||||||
Heat output kW | 14.98 | 23.6 | 33.1 | 41.74 | 46.5 | |||||||
Air discharge temperature ℃ | 31.1 | 34.5 | 33.2 | 34.7 | 34.2 | |||||||
Flow rate m³/h | 0.71 | 1.12 | 1.57 | 1.98 | 2.42 | |||||||
Water resistance kPa | 0.25 | 0.79 | 1.39 | 4.88 | 7.83 | |||||||
LTHW 70/50 at air intake temperature 15℃ and maximum air discharge temperature | ||||||||||||
Heat output kW | 12.3 | 19.3 | 27.1 | 34.11 | 38.26 | |||||||
Air discharge temperature ℃ | 28.5 | 30.9 | 29.9 | 31.1 | 30.8 | |||||||
Flow rate m³/h | 0.58 | 0.92 | 1.29 | 1.62 | 1.98 | |||||||
Water resistance kPa | 0.26 | 0.81 | 1.41 | 3.46 | 5.87 | |||||||
Pipe connections | ||||||||||||
Flow/return flow | 1″ | 1″ | 1″ | 1″ | 1″ | |||||||
Connection | Left | Left | Left | Left | Left |
Model | CD-100 | CD-150 | CD-200 | CD-250 | CD-300 | ||
Width | cm | 100 | 150 | 200 | 250 | 300 | |
Maks. installation height | M | 3.0 | 3.0 | 3.0 | 3.0 | 3.0 | |
Volume flow rate | Low speed | m³/jam | 2100 | 2800 | 4200 | 4900 | 5600 |
Medium speed | m³/jam | 2400 | 3200 | 4800 | 5600 | 6400 | |
High speed | m³/jam | 2700 | 3600 | 5400 | 6300 | 7200 | |
Maks. sound level | dB(A) | 59 | 60 | 62 | 63 | 64 | |
Weight of basic unit | kg | 48 | 68 | 88 | 118 | 138 |
Yes, they reduce the loss of conditioned air, lowering energy consumption and costs associated with heating and cooling.
Revolving door air curtain are customer made products according to different type of revolving door.
By two professional engineers, it only takes half a day, as we already finished assemble before packing and delivery.
Yes, we provide screen control as standard,we also can provide 485 connector with air curtain.
we provide strong wooden package with plastic cover, it is suitable for long distance delivery from China to other countries.
Our revolving doors not only enhance the aesthetics of buildings but also significantly improve energy efficiency and safety. Whether in the cold climates of Russia and Northern Europe or the hot conditions of the Middle East, our products have withstood harsh environments, earning widespread acclaim from customers. Our team continues to provide customized revolving door air curtain solutions for clients worldwide